The Bosch CCS Control Unit is the central power and control station for all CCS 900 Ultro Conference System contributor units, such as the chairman and delegate units. The control unit will supply power for up to 50 delegate / chairman units, and provide control for up to 150. The unit features a built in speaker and automated, programmable control over contributor units without the need for an operator. Plenty of connections allow for interfacing within paging systems, amplifier systems, recording devices and more. The unit is feature rich, however its control section is straightforward and intuitive to operate in any conference setting.
Specifications
Sample frequency |
Recording | 32Khz |
Playback | 32, 44.1 and 48Khz |
Bite rate: |
Recording | 64, 96, 128, 192, 256 Kbit/sec |
Playback | any bit rate |
Media |
MP3-tag | Compatible conform ID3V2 |
Memory card | Any SD card up to 2 GB compatible (high speed cards are advised). |
Line, telephone coupler and insertion in/outputs (unbalanced) |
Input sensitivity | -14 dBV / +11dBV (nominal/maximum) |
Input impedance | 33 kOhm |
Output level | -14 dBV / +11dBV (nominal/maximum) |
Output impedance | 500 Ohm |
Recorder in/output (unbalanced) - mono |
Input sensitivity | - 20 dBV / + 5 dBV (nominal/maximum) |
Input sensitivity adjustment | +0 / -20 dB |
Input impedance | 47 kOhm (for L and R channel) |
Output level | - 20 dBV/ + 5 dBV (nominal/maximum) |
Output impedance | 500 Ohm |
External microphone input (balanced) |
Input sensitivity | - 56 dBV (- 6 dBV via included adapter) |
Input sensitivity adjustment | +6 dB / -6 dB |
Phantom supply | 12V +/- 1V, 2 x 680 W (+/- 2%). (Phantom supply is not available when using the included adapter) |
Monitor loudspeaker |
Output level at 0.5 m | 72 dB SPL/ 82 dB SPL (nominal/maximum) |
Frequency response | 320 Hz ... 10 kHz (-10 dB, ref. 1kHz) |
Impedance | 25 ohm |
Volume control | 50 dB attenuation range |
Monitor headphone |
Output level | -8 dBV/ +2 dBV (nominal/maximum) |
Output impedance | 22 Ohm |
Output connection | stereo jack socket (mono output) |
Allowed impedance | any impedance |
Volume control | 50 dB attenuation range |
Loudspeaker volume control |
For Delegate and Chairman Units | mute (50 dB attenuation) + 10 steps of 1.9 dB |
Limiter threshold level | |
To unit loudspeaker / headphone | 10 dB above nominal level |
Gain reduction due to NOM |
Number of Open Microphones | NOM +/- 1 dB |
Auto microphone switch-off function selectable on the Control and Power Supply Unit | After approximately 30 sec. not speaking (sound level below 64 dB SPL) the microphone is automatically switched off |
System limits |
Number of Delegate / Chairman Units connected to CU | Maximum in total | 50 |
Maximum per trunk output | 25 |
Maximum trunk length using CCS 900 Ultro standard cabling | 100 m (328 ft.) |